OPTIMIZATION OF ENERGY CONSUMPTION

Stop the thousands of euros wasted to burn, heat, cool, air-condition.. The intervention of ROCHE TECHNOLOGIES has enabled many customers to halve their consumption of electricity, gas, or fuel. Among them, several industrialists were able at the same time to double their production capacity. The Return on Investment corresponding to the implementation of our recommendations is generally obtained over a period of less than 1 year.

BIOMASSE - BIOGAS - SYNGAS

For several years the expertise of ROCHE TECHNOLOGIES has been positioned at the heart of the ENERGY TRANSITION. Our interventions allow substantial gains in gas and steam production while drastically reducing carbon monoxide and dust emissions.



ENGINEERING MANAGEMENT

There are no problems, only solutions! ROCHE TECHNOLOGIES analyses, expertises, and solves any type of problem related to energy consumption and / or combustion. We bring the solutions and accompany you in their deployment.







COMBUSTION and FLUE GAS TREATMENT

have been the core business of ROCHE TECHNOLOGIES since its inception.  
In thermal processes such as incineration, sludge, waste, biomass, biogas or syngas, we have adapted furnaces and boilers to keep their waste load or heat load despite the variation in calorific value due to selective sorting and climatic conditions. At the same time, our interventions reduce both the emission of nitrogen oxides and carbon monoxide, as well as reduce clutches and fouling in furnaces and boilers. Our specific processes favor the absence of use of expensive reagents and more or less dangerous properties. The implementation of our recommendations results in results far exceeding legal standards.

STEP PIERRE BÉNITE GRAND LYON – FR
2015-2016
Rebuilding the reagent storage in the UF7 building.
Design and maintenance studies. Supply of process equipment.
Coordination of the site. MSI.
Incineration of sludge from STEP

SHOPPING CENTER SAINT MARTIAL LIMOGES-FR
DEPUIS 2005
2003-2009
Balance sheet in light of the energy optimization 
Operation optimisation 
Aid at the extension of shopping center (air conditioning)
2010-2013
Renovation of cooling towers and energy optimization (energy savings of 20%)
2015
Study of the replacement of gas boilers.

ENERGY RECOVERY CENTER LYON SUD-FR
2010-2014
2010-2012
Flue gas treatment maintenance and optimization of three incineration waste lines (scrubber, catalyst, heat exchanger)
2013 - 2014
Expertise of dysfunctions.
Repair of GEA FLUCOREX heat exchangers.
Replacement of valves and renovation of scrubbers in SVR.

ECOTUBE SYSTEM FOR FRANCE
DEPUIS 2004
2005: Coordination for achieving DeNOx compliance for Lons-le-Saunier, Bessieres ECONOTRE and for Pontmain Line 2 
2006: Pontmain, Line 2 Energy optimization Econotre 
2006: Injection of sludge Valezan-FR 
2007: MSVI Montargis-FR 
2008: Saint Ouen CPCU-FR 
2008: Besançon MSWI - FR 
2009: Saint Ouen CPCU -FR 
2011: SIDEC, The Gol Island-FR

AVR ROTTERDAM-NL
2011
Flue gas treatment maintenance and optimization of three incineration waste lines (scrubber, catalyst, heat exchanger)
INARIZ - LAMBALLE-FR
2010
Energy Optimization: process analysis and project
VIP LYON-FR
DEPUIS 2003
Expertise, technical advices, implementation of solutions: air conditioning, raising, infiltration, etc.. 
Malfunctions expertise, testing, suggestions for improvement and site supervision

MSWI METZ-FR
2008
Security survey HCl and Dioxins / Furans 
Site survey and documents analysis 
Analysis of the operation: combustion, flue gas treatment, operating 
Proposals for improvement

MSWI SENS-FR
2007
Optimization of the energy of the recovery plant coupled to the district heating network 
Proposal of operating improvement 
Study of electrical recovery

MSWI VITRE-FR
2007-2010
2007-2009: 
Combustion stabilisation with high calorific values and limitation of boiler fouling.
Site Expertise, tests, implementation of BrumiDeNOx system, reduction of fouling of boilers, capacity enhancement in case of household waste with high calorific value.
DeNOx efficiency, NOx <200 mg/Nm3 without chemical additives.
2010: 
Assistance for the implementation and commissioning of the heating network and energy recovery in the plant

MSWI MULHOUSE-FR
2006
For the Cabinet Merlin: expertise on disfunctions CO / NOx / Dioxins, analysis of the existing systems, testing and proposals for modification
MSVI BELFORT SERTRID-FR
2004
Expertise bilan de fin de réalisation d'une usine d'incinération neuve de 2 lignes. 
Étude des réclamations, propositions d’accords entre le maître d’ouvrage et les fournisseurs.

MSWI LIMOGES STVL- ONYX -FR
2003
Expertise of dysfunctions and proposals for solutions including compliance to 2005 standard
MSWI OF MANS-FR
2003
Expertise dysfunctions of the new flue gas treatment 
Resolutions proposal

MSWI MONTBELIARD-FR
2003
Site expertise 
Proposals for optimization of capacity and technical tests 
Results: Increased Capacity> 10%

VITRY HABITAT-FR
2003
Combustion and control system expertise 
Tests on the 5.5 MW boiler: reduction of CO by a factor of 5 
Proposals for implementation and renovation

C&A COMPANY-FR
2003-2009
Expertise, advice, testing, legionella monitoring for group C & A (80 buildings) 
Presentation of Legionella and its environmental consequences 
Conducting a monitoring procedure (twice a year with relevant centers) 
Monitoring: 2003-2009

CC LES TROIS SOLEILS RENNES-FR
DEPUIS 2003
Expertise and problem solving of air conditionning noise 
Expertise and treatment of legionella problems within the sanitary hot water and the cooling systems 
Tips and monitoring of changes: 
- the previous systems 
- the replacement of open evaporative cooling towers by closed air coolers